Vasc Pro™ Vascular Ultrasound Table

The Vasc Pro™ Vascular Ultrasound Table is designed with ergonomics in mind.

It addresses sonographer comfort and safety and proper patient positioning, virtually eliminating repetitive-strain injuries from vascular scanning. Sonographer comfort and safety are accomplished through features such as the new adjustable foot support that accommodates patients of various heights, and optional side rails enabling close access to the patient without sonographer contortion. 

Fowler positioning to 80°, which accommodates natural body extension and sitting position without slide or shift, an optional Articulating Scanning Arm Board adjustable from 0° to 130° locking every 10°, the thick antimicrobial mattress and adjustable nature of the table all create a comfortable imaging experience for the patient.

Dimensions

 L 73" x W 30" (185.4 x 76.2cm); W 35" (88.9cm) with optional side rails

Motions

Height Adjustable 23" to 39" (58.4 to 99cm)
Trendelenburg 0° to 15° 
Reverse Trendelenburg 0° to 30° 
Fowler Postioning 0° to 80° infinitely adjustable 

Controls

Hand Control Activates height, Trendelenburg motions, Fowler positioning and auto level motions
Foot Control Activates height, Trendelenburg motions, and Fowler positioning 

Wheels

5" (12.7cm) Individual locking swivel casters; central floor-locking system

Tabletop

Two primary sections: torso section with Fowler positioning; lower body section remains fixed

Foot Support

Adjustable every 2", up to 14"

Mattress

Torso section 2" (5cm) thick, lower body section 3" (7.6cm) thick; Naugahyde®, antimicrobial mattress cover with Advanced BeautyGard® provides protection against bacteria

Upholstery Color

Graphite 

Patient Restraints

Three body straps

Finish

Powder coat

Patient Capacity

500lb (227kg); weight tested to four times the patient load rating

Weight

335lb (152kg)

Power

115 VAC (058-732) or 230 VAC (058-733)

Suitable Procedures

Lower Extremity

  • Venous Mapping and Doppler (DVT)

  • Venous Reflux

  • Venous Insufficiency

  • Venous Ablation

  • Arterial Scan/Doppler (PAD)

Upper Extremity

  • Arterial

  • Venous Access Placement and Assessment*

  • Carotid

  • Carotid Duplex

  • Transcranial

  • Abdomen

  • Aorta

  • Thyroid

  • Breast

  • Renal

  • Renal Transplant

  • Renal Artery

  • Testicular

  • Musculoskeletal

  • SMA

*Requires optional vascular arm board.

Documents

Sorry, there are no documents available for this product.

The LabLogic Group will always treat your details with the utmost care and will never sell them to third party companies.

Please choose one of the following:



    Previous
    Next