Easy to use, easy to understand.

The Atomlab® Wipe Test Counter is easy to use, easy to understand, fast and dependable. A  touchscreen display utilizing intuitive software eliminates the tedium of wipe testing. Simply perform a daily calibration and background count, then count the wipe for each predetermined location. Trigger levels can be set for any isotope at any location including 200dpm for iodine. In seconds the system will determine if the location is above or below the user defined trigger level.

When performing a wipe test, the full spectrum is displayed. A wide window that includes the isotope energies expected in a particular department is set by the user. The efficiencies of the isotopes selected for the window can be either factory defaults or user determined using an integrated detector efficiency program. Individual isotope ROIs along with the wide window can be set. This feature helps identify the isotope(s) causing contamination.

The user may define an unlimited number of “Area” names and wipe “Locations” and designate them as restricted area, unrestricted area, sealed source or package. The Wipe Test Program automatically calculates net contamination levels and reports results in dpm, uCi and Bq.

The system consists of a lead shielded 2" x 2" sodium iodide (NaI) well detector and a 64 channel multichannel analyzer. The displayed energy range (spectrum) is 0-800 KeV, which is typically found in nuclear medicine departments.

The wipe counter is designed to meet or exceed all NRC (10 CFR 35.70, 10 CFR 20.1906 and 10 CFR 35.2067) and state wipe test requirements. There are automated programs for the quality assurance functions: calibration, FWHM, chi-square and minimum detectable activity (MDA).

Wipe test results and QA test data can be stored in memory and printed at any time.

 

Display

All-In-One Flat Panel Display

12.2" Touchscreen, Windows 10 Operating System and USB connectivity.

Dimensions

W 11.8" x D 8.1" x H 0.4" (30 x 21 x 1cm)

Line Voltage

100 to 240 VAC, auto selectable by the power supply

Line Frequency

50/60 Hz, detachable line cord, built-in EMI filter and transient suppression

Auxillary Ports

Two USB ports, one RS-232 port

Memory

Stores wipe, calibration, background, high voltage, isotope specification, isotope efficiency, Chi-Square testing results, technologist list, wipe locations list and latest MDA calculation. Results can be displayed and printed.

Preset Radionuclides

33 including Tc-99m, Co-57, Cs-137, Ga-67, Tl-201, I-123, I-125, I-131, In-111, F-18

 
Well Counter

Dimensions

D 6" x H 11" (15.24 x 27.9 cm)

Weight

29 lb (13.2 kg)

Detector

2" x 2" NaI (Tl) integral line scintillation detector with a 0.75" dia x 1.44" depth well (1.9 x 3.7 cm)

Style

Remote Detector

Channels

64

MCA

Integral to Well Counter

Spectral Resolution

FWHM 10%

Count Rate

30,000 cps (Maximum)

Lead Shielding

0.5" thick (1.2 cm) integral lead shield    

Manual MCA Program

For performing sample counts and analysis beyond the scope of the standardized programs.

  • Expandable library of 33 commonly used isotopes
  • Unlimited user-defined isotopes
  • Two counting methods: preset time and preset ROI

In addition to providing “standardized” programs for routine test and survey procedures, the Atomlab 500 now offers a “manual” program to accommodate other counting and spectrum analysis tasks. The user can select from three counting methods: preset time, preset ROI counts, and continuous counting. After any count, the Spectrum Analysis option can be used to produce a Spectrum Analysis Report. The monitor shows when a test is in progress, and graphically displays the spectrum, time, counts and cpm.

Documents

Sorry, there are no documents available for this product.

The LabLogic Group will always treat your details with the utmost care and will never sell them to third party companies.

Please choose one of the following:



    Previous
    Next