identiFINDER R200 is a rugged, pager-sized Spectroscopic Personal Radiation Detector (SPRD).
The R200 provides full ANSI N42.32 Personal Radiation Detector (PRD) compliance and features next-generation solid state detector read-out technology that delivers ANSI N42.48 SPRD compliance with nuclide identification. The clear user interface and simple data presentation common to all identiFINDER products allow it to quickly integrate with existing operational protocols and reduce the training burden.
Radioisotope Identification
The ability to identify specific gamma sources enables front-line responders to perform immediate detection and response during a radiological event. FLIR's new SiPM technology in combination with Cesium Iodide (CsI) detector provides high-fidelity identification (≤7.5% resolution) so front-line officers can quickly determine whether a radiation source is a true threat or benign source from medical patients, normally occurring radiation, or industrial use. The identiFINDER R200 uses this next-generation solid state detector read-out technology to advance a radiological event from “alarm and wait” to “identify and take action.”
Pager-Sized and Rugged
At less than one pound, the identiFINDER R200 is lightweight and rugged enough to wear it on a belt without burdening the user. It is 1.5 meter drop-tested and IP67-rated so operators can wear it with confidence during routine traffic stops or high visibility events and in mass transit or critical infrastructure entry control points. It has a long-lasting internal rechargeable battery with additional external battery compartment for extended field situations. The identiFINDER R200 performs automatic calibration and stabilization and doesn’t require any user maintenance.
Shared Common User Interface
The identiFINDER R-series of products share a field-proven, common user interface and simple data presentation. With over 20,000 identiFINDER products deployed globally, the familiar interactions with the identiFINDER R200 allow it to quickly integrate with existing operational protocols while also reducing the training burden. Using the latest advancements in Bluetooth® and web server technologies, the OneTouch Reachback™ feature enables officers to send immediate notifications to other responders before arriving on-scene providing large-scale situational awareness.
identiFINDER R200 Spectroscopic Personal Radiation Detector (SPRD) features
- Pager-sized and wearable (less than 0.9 lbs)
- ANSI N42.32 PRD standard fully compliant
- ANSI N42.48 SPRD standard fully compliant with nuclide identification
- SiPM technology with CsI provides ≤ 7.5% resolution
- Crisp, clear display in full sunlight and low light conditions
- Single-hand operation with three-button control
- Common user interface with other FLIR radiation detectors
- ≥ 36-hour battery life, plus additional 18-hour replaceable battery
- No consumables or user maintenance
- Internal web server for easy data retrieval
- OneTouch Reachback
R200 neutron detection
As an added feature to cesium iodide for gamma radiation detection and identification, the identiFINDER R200 can be equipped with zinc sulfide (ZnS) to provide neutron measurement in a ruggedised, drop-tested, IP67 product.
Documents
-
FLIR R200 Datasheet
Download (1.71 MB)